next Guangxi Shelf The factory will introduce the precautions when installing and placing shelves here, as follows:
1. When installing shelves, one or more signs must be set up at relatively obvious places on the shelves. The area of each sign shall not be less than 20 square centimeters. Average load (kg), the quantity of unit load allowed to be stored in each compartment.
2. The settlement value of the base of the integrated storage rack shall be strictly controlled to ensure the normal use of the rack structure. When installing the non warehouse frame integrated shelf, attention should be paid to the separation of the shelf foundation and the building column foundation to prevent the damage to the building caused by the shelf structure stress.
3. The column base of the rack column shall be correctly fixed on the concrete foundation. It is necessary to know whether the connection mode between the shelf and the ground is the scheme of embedded parts, secondary watering, or the scheme of direct connection between chemical bolts and the ground. The diameter of bolts and the small size of embedded parts must be determined according to the actual load, seismic load or wind load calculation. Small shelves loaded manually below 2.4m may not be fixed. The concrete of the fixed frame column foundation must be cured continuously for 29 days, and bear the corresponding pressure. The uneven settlement must meet the use requirements.
4. When installing the cross beam frame, it should be noted that the two ends of each cross beam must be equipped with locking devices, or provide places for fastening screws and nuts, so that the cross beam can be firmly fixed on the column to prevent it from being separated by upward external forces. In order to ensure the engagement of the beam and its locking device, the normal operation of the beam locking device or the tightening of screws and nuts should be checked regularly during use, and the damaged device should be replaced in time.
5. Installation Guangxi Heavy Shelf In structure, factors such as use requirements, equipment conditions, load characteristics, material supply and installation conditions shall be comprehensively considered, and the structural form, structural measures and production materials shall be reasonably selected to achieve advanced technology, economic rationality, safety, applicability and guarantee. Quality.